MOLT & MOSS NEOCARIDINA DECISION CARD Version: 1.0 Reviewed: 2026-08-12 Topic: Read ammonia, nitrite and nitrate correctly Situation: Ammonia, nitrite or nitrate is being used to judge readiness or a change. Observe first: Identify the analyte, reporting basis, unit, test resolution, pH, temperature, recent feed and recent livestock or filter changes. First action: Confirm the result and protect animals from a continuing measured hazard while investigating source and system function. Record next: Record exact analyte and basis, method, before and after values, pH, temperature, actions, deaths and recovery observations. Stop boundary: Do not equate TAN with un-ionized ammonia, use one nitrate result as proof of cycling or invent a universal chronic safe threshold. Permanent card: https://moltandmoss.com/care/action-cards/nitrogen Governing guide: https://moltandmoss.com/care/nitrogen This card is a first-decision aid, not a diagnosis, treatment authorization, complete method or substitute for the governing guide.